Cardiac auscultation teaching recordings — CirCor DigiScope / PhysioNet v1.0.3 https://physionet.org/content/circor-heart-sound/1.0.3/ DOI: 10.13026/tshs-mw03 Original authors: Jorge Oliveira, Francesco Renna, Paulo Costa, Marcelo Nogueira, Ana Cristina Oliveira, Andoni Elola, Carlos Ferreira, Alipio Jorge, Ali Bahrami Rad, Matthew Reyna, Reza Sameni, Gari Clifford and Miguel Coimbra (2022). Original publication: Oliveira et al., The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. IEEE J Biomed Health Inform. DOI: 10.1109/JBHI.2021.3137048. License stated by the dataset: Open Data Commons Attribution License v1.0. Full license: LICENSE.txt. Twenty-four excerpts from the publicly released training set were used, four recorded sites from each of six deidentified participants. The focus abbreviation is retained in the file name. The manifest lists original URLs, SHA-256 hashes, source crop times, and the SHA-256 of every excerpt. normal: source record 49653 — Murmur Absent; Outcome Normal. systolic: source record 40840 — Murmur Present at AV+MV+PV+TV; most audible PV; mid-systolic diamond-shaped harsh murmur; Outcome Abnormal. diastolic: source record 50238 — Murmur Present at AV+MV+PV+TV; most audible MV; early-diastolic decrescendo blowing murmur and early-systolic murmur; Outcome Abnormal. Adaptation of reference recordings: each excerpt starts at an annotated S1 and ends at an annotated S1 up to eight beats later. An 8 ms edge fade reduces clicks. The reference files have not been pitch-shifted, time-stretched, filtered, or attributed to a specific valve disease. They were collected at four sites separately, not simultaneously. They are pediatric/adolescent recordings; murmur annotations do not establish a valve diagnosis. Reference playback pauses the independent teaching model. Site-specific synchronized S1/S2 tones (2026-10-05): tones/av-s1.wav, av-s2.wav, pv-s1.wav, pv-s2.wav, tv-s1.wav, tv-s2.wav, mv-s1.wav, mv-s2.wav are derived from the normal 49653 recordings already cited above. scripts/prepare-site-tones.py extracts one annotated S1 and S2 at each site, removes DC, applies 2/10 ms edge fades and one common gain. No pitch shift or individual peak normalization. tones/site-tones.json documents crop offsets and hashes. These derived tones retain the CirCor / ODC-By attribution. Mixing and relative emphasis between sites, Erb and radiation regions are illustrative, not a measured acoustic field. Additional cases (2026-10-05): holosystolic: 45843 — holosystolic decrescendo blowing I/VI; MV+TV, loudest MV. harsh: 85207 — holosystolic plateau harsh III/VI; all four sites, loudest TV. early: 68204 — early-systolic plateau blowing I/VI; PV, loudest PV. Atrial fibrillation now schedules these CirCor-derived site-specific S1/S2 tones with variable RR and intensity. Coordinated atrial shortening is suppressed in the 3D schematic. This is synthesized teaching, not a CirCor AF recording. Reference: 2023 ACC/AHA/ACCP/HRS Guideline for AF, https://pmc.ncbi.nlm.nih.gov/articles/PMC11095842/. The aortic stenosis, mitral regurgitation, aortic regurgitation and mitral stenosis murmurs and opening snap are original noise synthesis, not copied clinical recordings. Timing, quality and radiation follow educational descriptions referenced in docs/auscultation-3d.md. Their 3D and pressure/volume examples are illustrative, not patient measurements or disease-severity estimates. No MSD or AHA media are redistributed. The recording catalog public/auscultation/library.json records attribution and license for each entry, including future independently sourced registrations. New recordings must preserve their source-specific credits, usage rights and documented clinical annotations.